Trolley-type hot-air oven for drying transformer coils and core-coil assemblies, ambient to 200°C.

Also called a transformer drying oven, transformer core drying oven or transformer coil oven.

Photo shown is a representative image.

Key Features

  • Trolley on rails for heavy active parts

  • Moisture exhaust blower

  • Redundant temperature controllers

  • Recorder for the drying record

  • Independent safety thermostat

  • Chamber sized to your largest transformer

Specifications

Working range: ambient to 200°C (200°C design)

Uniformity: within ±10°C

Heating: finned electric elements; LPG/PNG indirect option

Example: 132 kW oven, 180°C operating

Airflow: two top circulation blowers + moisture exhaust blower

Insulation: 150 mm glass wool

Loading: trolley on rails

Controls: redundant master/slave controllers, K-type thermocouples, recorder, safety thermostat

Industries: Transformers, electrical equipment, transformer repair

Need Sizing & Price for This Equipment?

Speak with an Engineer (New Delhi): +91-98105-20120 | WhatsApp: +91-99999-79441

About the Transformer Core Dryer

Paper and pressboard insulation in a transformer absorbs moisture during winding and assembly. Wet insulation lowers dielectric strength and shortens transformer life, so coils and core-coil assemblies are dried before they are tanked and filled with oil. A transformer core dryer is a large hot-air oven built for this job. A trolley on rails carries the active part into an insulated chamber. Circulating hot air heats it evenly, and an exhaust blower carries off the moisture as it is driven out.

 

AHS has built transformer coil ovens for transformer makers in India and the Gulf. A typical build has finned heating elements, two top-mounted circulation blowers, an exhaust blower for moisture, a trolley on rails, a strip-chart or digital recorder and a safety thermostat. One 132 kW oven was rated for 180°C operating and 200°C design temperature. It had 150 mm glass-wool insulation, contactor control, redundant master and slave controllers and K-type thermocouples. Our transformer ovens are specified for temperature uniformity within ±10°C, working from ambient to 200°C. Drying temperatures and times are set by the transformer maker's procedure.

 

This page covers hot-air drying in air. For drying under vacuum without vapour, see the Vacuum Chamber. For small motor windings, see the Motor Coil Dryer. Send us the largest active part size and weight, kVA range and drying cycle, and we will size the chamber, heating and airflow.

 

Typical applications

  • Drying distribution transformer coils

  • Drying core-coil assemblies before tanking

  • Drying pressboard and insulation parts

  • Baking varnish on transformer windings

  • Re-drying repaired transformers

 

Common questions

Why must transformer coils be dried?

Moisture in paper insulation lowers dielectric strength and speeds ageing. Drying before oil filling protects the transformer.

 

What temperature does a transformer core dryer run at?

Our ovens work from ambient to 200°C. The drying temperature and time come from the transformer maker's procedure.

 

What is the difference from a vapour phase drying oven?

This oven dries with hot air. Vapour phase drying heats with solvent vapour under vacuum, and is faster for large units.

 

How even is the temperature?

Our transformer ovens are specified for uniformity within ±10°C.

 

Can you supply a recorder?

Yes. A recorder for the drying cycle is standard.

 

Related ovens and furnaces

 

Need a quotation? Share your load size, working temperature and fuel, and we will suggest a design. Call +91 98105 20120, message us on WhatsApp or send an enquiry. For a quick figure first, try our oven heat load calculator.