How an Industrial Oven Is Tested Before Dispatch: Heat Run and Temperature Survey
An oven that has only been assembled has not been proved. Before dispatch it should be run hot and measured, so that problems are found at the maker's works and not on your shop floor. This is the sequence AHS follows at its New Delhi works.
The short answer
An industrial oven is checked for dimensions and build quality, tested electrically, run through its burner safety sequence if it is gas fired, heated to working temperature with no load, and then surveyed for temperature uniformity with nine thermocouples.
Step by step
Dimensional check: the chamber, trolleys, trays and door openings are checked against the approved drawing.
Physical inspection: insulation, door seal and casing are inspected.
Electrical checks: wiring, insulation resistance, interlocks, and heater current balance on all three phases.
Burner sequence test on gas fired ovens: pre-purge, ignition, flame proving and flame-failure lockout.
No-load heat run: the oven is taken to working temperature with the blower and exhaust running.
Temperature uniformity survey: nine thermocouples are placed at the eight corners of the working volume and at the centre. Readings are logged after the chamber has stabilised at the set point.
How the survey result is reported
The report gives the largest deviation from the set point and compares it with the uniformity promised in the offer. Depending on chamber size and design, AHS ovens are offered with a uniformity between ±1°C and ±5°C. The figure for each oven is stated in the offer and checked before dispatch. The survey can be repeated at further set points on request.
Can the customer witness the test?
Yes. Customers or their consultants can witness the pre-dispatch heat run and temperature survey at the New Delhi works. The test and survey checklist is available on request with a quotation.
What to ask any supplier
Will the oven be heat-run to working temperature before dispatch?
How many thermocouples are used in the survey, and where are they placed?
What uniformity is promised, and at which set point?
Can we witness the test, and do we get the report?
More detail is on our quality and testing page.
To discuss your requirement, call +91 98105 20120 or send an enquiry. Every AHS oven and furnace is designed and built to order in New Delhi.




Comments