top of page

Home  /  Products  /  Chamber Type Furnace

Chamber Type Furnace

Front-loading electric chamber furnace for industrial hardening, annealing and normalising, to 1,150°C.

Also called a box furnace, box type furnace or chamber bhatti.

Key Features

  • Front loading for daily production

  • Low element surface loading for long life

  • Profile control with data logging option

  • Roller-top charging table for heavy parts

  • Low-mass fibre lining for fast heat-up

  • Temperature accuracy within ±5°C

Specifications

Maximum temperature: 1,100–1,150°C

Working range: 1,000–1,100°C

Example: 450 mm chamber height, 15 kW, accuracy within ±5°C

Elements: Kanthal A1 coil on ceramic refractory, up to 1.5 W/cm²

Insulation: 6 mm ceramic paper + 250 mm ceramic wool, or 115 mm alumina fibre modules

Shell: 5 mm MS

Controls: PID 0–1,200°C, K-type thermocouple, SCR; PLC/HMI with LAN logging optional

Options: thyristor control, cooling fan, roller-top charging table

Industries: Steel forging and casting, tools and dies, engineering

About the Chamber Type Furnace

A chamber type furnace, also called a box furnace, is the workhorse heat treatment furnace for industrial batches. Parts are loaded through a front door onto a hearth, heated to temperature, soaked, and drawn out for quenching or cooling. It covers hardening, annealing, normalising, tempering and stress relief of tools, dies, forgings and machined parts. Loads are larger than a lab muffle furnace can take, and the furnace is built for daily production.

 

AHS chamber furnaces are electric, with Kanthal A1 coil elements on ceramic refractory, and are rated to 1,100–1,150°C with 1,000–1,100°C working. One 2023 build had a 450 mm chamber height, 15 kW of heating and temperature accuracy within ±5°C. It was insulated with 6 mm ceramic paper and 250 mm ceramic wool and controlled by a 0–1,200°C PID with K-type thermocouple and SCR. Options were thyristor control, a 7-inch PLC/HMI profile controller with LAN data logging, a PLC cooling fan and a roller-top charging table for heavy parts. High-temperature designs use 115 mm compressed ceramic-fibre modules of 70% alumina, Kanthal A1 elements at a low surface loading of up to 1.5 W/cm² on high-alumina grooved tiles for long life, and a 5 mm MS shell.

 

For lab and tool-room sizes, see also our Muffle Furnace. For loads too heavy to slide in, see the Bogie Hearth Furnace. For quench-hardening lines, see the Hardening Furnace. Tell us the chamber size, maximum temperature, load weight and process, and we will specify kW, elements and controls.

 

Typical applications

  • Hardening tools, dies and machined parts

  • Annealing and normalising forgings

  • Stress relieving small fabrications

  • Heat treating samples and prototypes

  • Tempering after hardening

 

Common questions

What temperature does the chamber furnace reach?

Up to 1,100–1,150°C, with 1,000–1,100°C working.

 

How accurate is the temperature?

Our recent chamber furnace was specified for accuracy within ±5°C.

 

How is it different from a muffle furnace?

Muffle furnaces are lab and tool-room sizes. The chamber furnace takes larger industrial loads.

 

Can I log the heat treatment cycle?

Yes. A PLC/HMI profile controller with LAN data logging is available.

 

How long do the elements last?

We run Kanthal A1 elements at low surface loading on grooved high-alumina tiles for long life.

 

Related ovens and furnaces

 

Need a quotation? Share your load size, working temperature and fuel, and we will suggest a design. Call +91 98105 20120, message us on WhatsApp or send an enquiry. For a quick figure first, try our oven heat load calculator.

bottom of page